Nuc Frequency(MHz) Abund(%) Spin QuadMoment Receptivity Reference Literature
H1 100.0000000 99.9885 0.5 0.00000e+00 1.000e+00 Me4Si, 1% in CDCl3 LIT: IUPAC (2001)
H2 15.3506084103 0.0115 1.0 2.86000e-01 1.110e-06 DSS LIT: Wishart, J. Biomol. NMR 12, 1-23 (1998); extra digits by Varian
lk 15.3506084103 0.0115 1.0 2.86000e-01 1.110e-06 DSS LIT: Wishart, J. Biomol. NMR 12, 1-23 (1998); extra digits by Varian
H3 106.6639740 0.0000 0.5 0.00000e+00 0.000e+00 Me4Si-t1 LIT: IUPAC (2001)
He3 76.1794370 0.0001 0.5 0.00000e+00 6.060e-07 He gas LIT: IUPAC (2001)
Li6 14.7160860 7.5900 1.0 -8.08000e-02 6.450e-04 LiCl / D2O, 9.7 M LIT: IUPAC (2001)
Li7 38.8637970 92.4100 1.5 -4.01000e+00 2.710e-01 LiCl / D2O, 9.7 M LIT: IUPAC (2001)
Be9 14.0518130 100.0000 1.5 5.28800e+00 1.390e-02 BeSO4 / D2O, 0.43 M LIT: IUPAC (2001)
B10 10.7436580 19.9000 3.0 8.45900e+00 3.950e-03 BF3.Et2O / CDCl3 LIT: IUPAC (2001)
B11 32.0839740 80.1000 1.5 4.05900e+00 1.320e-01 BF3.Et2O / CDCl3 LIT: IUPAC (2001)
C13 25.1450200 1.0700 0.5 0.00000e+00 1.700e-04 Me4Si, 1% in CDCl3 LIT: IUPAC (2001)
N14 7.2263170 99.6320 1.0 2.04400e+00 1.000e-03 CH3NO2 (neat/CDCl3) LIT: IUPAC (2001)
N15 10.1367670 0.3680 0.5 0.00000e+00 3.840e-06 CH3NO2 (neat/CDCl3) LIT: IUPAC (2001)
O17 13.5564570 0.0380 2.5 -2.55800e+00 1.110e-05 D2O (neat) LIT: IUPAC (2001)
F19 94.0940110 100.0000 0.5 0.00000e+00 8.340e-01 CCl3F LIT: IUPAC (2001)
Ne21 7.8942960 0.2700 1.5 1.01550e+01 6.650e-06 Ne gas, 1.1 MPa LIT: IUPAC (2001)
Na23 26.4519000 100.0000 1.5 1.04000e+01 9.270e-02 NaCl / D2O, 0.1 M LIT: IUPAC (2001)
Mg25 6.1216350 10.0000 2.5 1.99400e+01 2.680e-04 MgCl2 / D2O, 11 M LIT: IUPAC (2001)
Al27 26.0568590 100.0000 2.5 1.46600e+01 2.070e-01 Al(NO3)3 / D2O, 1.1 M LIT: IUPAC (2001)
Si29 19.8671870 4.6832 0.5 0.00000e+00 3.680e-04 Me4Si, 1% in CDCl3 LIT: IUPAC (2001)
P31 40.4807420 100.0000 0.5 0.00000e+00 6.650e-02 H3PO4 LIT: IUPAC (2001)
S33 7.6760000 0.7600 1.5 -6.78000e+00 1.720e-05 (NH4)2SO4 / D2O, sat. LIT: IUPAC (2001)
Cl35 9.7979090 75.7800 1.5 -8.16500e+00 3.580e-03 NaCl / D2O, 0.1 M LIT: IUPAC (2001)
Cl37 8.1557250 24.2200 1.5 -6.43500e+00 6.590e-04 NaCl / D2O, 0.1 M LIT: IUPAC (2001)
K39 4.6663730 93.2581 1.5 5.85000e+00 4.760e-04 KCl / D2O, 0.1 M LIT: IUPAC (2001)
K40 5.8020180 0.0117 4.0 -7.30000e+00 6.120e-07 KCl / D2O, 0.1 M LIT: IUPAC (2001)
K41 2.5613050 6.7302 1.5 7.11000e+00 5.680e-06 KCl / D2O, 0.1 M LIT: IUPAC (2001)
Ca43 6.7300290 0.1350 3.5 -4.08000e+00 8.680e-06 CaCl2 / D2O, 0.1 M LIT: IUPAC (2001)
Sc45 24.2917470 100.0000 3.5 -2.20000e+01 3.020e-01 Sc(NO3)3 / D2O, 0.06 M LIT: IUPAC (2001)
Ti47 5.6375340 7.4400 2.5 3.02000e+01 1.560e-04 TiCl4 (neat) LIT: IUPAC (2001)
Ti49 5.6390370 5.4100 3.5 2.47000e+01 2.050e-04 TiCl4 (neat) LIT: IUPAC (2001)
V50 9.9703090 0.2500 6.0 2.10000e+01 1.390e-04 VOCl3 (neat/C6D6) LIT: IUPAC (2001)
V51 26.3029480 99.7500 3.5 -5.20000e+00 3.830e-01 VOCl3 (neat/C6D6) LIT: IUPAC (2001)
Cr53 5.6524960 9.5010 1.5 -1.50000e+01 8.630e-05 K2CrO4 / D2O, sat. LIT: IUPAC (2001)
Mn55 24.7892180 100.0000 2.5 3.30000e+01 1.790e-01 KMnO4 / D2O, 0.82 M LIT: IUPAC (2001)
Fe57 3.2377780 2.1190 0.5 0.00000e+00 7.240e-07 Fe(CO)5 / C6D6 LIT: IUPAC (2001)
Co59 23.7270740 100.0000 3.5 4.20000e+01 2.780e-01 K3[Co(CN)6] / D2O, 0.56 M LIT: IUPAC (2001)
Ni61 8.9360510 1.1399 1.5 1.62000e+01 4.090e-05 Ni(CO)4 (neat/C6D6) LIT: IUPAC (2001)
Cu63 26.5154730 69.1700 1.5 -2.20000e+01 6.500e-02 [Cu(CH3CN)4][ClO4] / CH3CN, sat. LIT: IUPAC (2001)
Cu65 28.4036930 30.8300 1.5 -2.04000e+01 3.540e-02 [Cu(CH3CN)4][ClO4] / CH3CN, sat. LIT: IUPAC (2001)
Zn67 6.2568030 4.1000 2.5 1.50000e+01 1.180e-04 Zn(NO3)2 / D2O, sat. LIT: IUPAC (2001)
Ga69 24.0013540 60.1080 1.5 1.71000e+01 4.190e-02 Ga(NO3)3 / D2O, 1.1 M LIT: IUPAC (2001)
Ga71 30.4967040 39.8920 1.5 1.07000e+01 5.710e-02 Ga(NO3)3 / D2O, 1.1 M LIT: IUPAC (2001)
Ge73 3.4883150 7.7300 4.5 -1.96000e+01 1.090e-04 (CH3)4Ge (neat) LIT: IUPAC (2001)
As75 17.1226140 100.0000 1.5 3.14000e+01 2.540e-02 NaAsF6 / CD3CN, 0.5 M LIT: IUPAC (2001)
Se77 19.0715130 7.6300 0.5 0.00000e+00 5.370e-04 Me2Se, neat/C6D6 LIT: IUPAC (2001)
Br79 25.0539800 50.6900 1.5 3.13000e+01 4.030e-02 NaBr / D2O, 0.01 M LIT: IUPAC (2001)
Br81 27.0065180 49.3100 1.5 2.62000e+01 4.910e-02 NaBr / D2O, 0.01 M LIT: IUPAC (2001)
Kr83 3.8476000 11.4900 4.5 2.59000e+01 2.180e-04 Kr gas LIT: IUPAC (2001)
Rb85 9.6549430 72.1700 2.5 2.76000e+01 7.670e-03 RbCl / D2O, 0.01 M LIT: IUPAC (2001)
Rb87 32.7204540 27.8300 1.5 1.33500e+01 4.930e-02 RbCl / D2O, 0.01 M LIT: IUPAC (2001)
Sr87 4.3338220 7.0000 4.5 3.35000e+01 1.900e-04 SrCl2 / D2O, 0.5 M LIT: IUPAC (2001)
Y89 4.9001980 100.0000 0.5 0.00000e+00 1.190e-04 Y(NO3)3 / H2O/D2O LIT: IUPAC (2001)
Zr91 9.2962980 11.2200 2.5 -1.76000e+01 1.070e-03 Zr(C5H5)2Cl2 / CH2Cl2, sat. LIT: IUPAC (2001)
Nb93 24.4761700 100.0000 4.5 -3.20000e+01 4.880e-01 K[NbCl6] / CH3CN, sat. LIT: IUPAC (2001)
Mo95 6.5169260 15.9200 2.5 -2.20000e+00 5.210e-04 Na2MoO4 / D2O, 2 M LIT: IUPAC (2001)
Mo97 6.6536950 9.5500 2.5 2.55000e+01 3.330e-04 Na2MoO4 / D2O, 2 M LIT: IUPAC (2001)
Tc99 22.5083260 0.0000 4.5 -1.29000e+01 0.000e+00 NH4TcO4 / D2O LIT: IUPAC (2001)
Ru99 4.6051510 12.7600 2.5 7.90000e+00 1.440e-04 K4[Ru(CN)6] / D2O, 0.3 M LIT: IUPAC (2001)
Ru101 5.1613690 17.0600 2.5 4.57000e+01 2.710e-04 K4[Ru(CN)6] / D2O, 0.3 M LIT: IUPAC (2001)
Rh103 3.1864470 100.0000 0.5 0.00000e+00 3.170e-05 Rh(acac)3 / CDCl3, sat. LIT: IUPAC (2001)
Pd105 4.5761000 22.3300 2.5 6.60000e+01 2.530e-04 K2PdCl6 / D2O, sat. LIT: IUPAC (2001)
Ag107 4.0478190 51.8390 0.5 0.00000e+00 3.500e-05 AgNO3 / D2O, sat. LIT: IUPAC (2001)
Ag109 4.6535330 48.1610 0.5 0.00000e+00 4.940e-05 AgNO3 / D2O, sat. LIT: IUPAC (2001)
Cd111 21.2154800 12.8000 0.5 0.00000e+00 1.240e-03 Me2Cd (neat) LIT: IUPAC (2001)
Cd113 22.1931750 12.2200 0.5 0.00000e+00 1.350e-03 Me2Cd (neat) LIT: IUPAC (2001)
In113 21.8657550 4.2900 4.5 7.99000e+01 1.510e-02 In(NO3)3 / D2O, 0.1 M LIT: IUPAC (2001)
In115 21.9126290 95.7100 4.5 8.10000e+01 3.380e-01 In(NO3)3 / D2O, 0.1 M LIT: IUPAC (2001)
Sn115 32.7187490 0.3400 0.5 0.00000e+00 1.210e-04 Me4Sn, neat/C6D6 LIT: IUPAC (2001)
Sn117 35.6322590 7.6800 0.5 0.00000e+00 3.540e-03 Me4Sn, neat/C6D6 LIT: IUPAC (2001)
Sn119 37.2906320 8.5900 0.5 0.00000e+00 4.530e-03 Me4Sn, neat/C6D6 LIT: IUPAC (2001)
Sb121 23.9305770 57.2100 2.5 -3.60000e+01 9.330e-02 KSbCl6 / CH3CN, sat. LIT: IUPAC (2001)
Sb123 12.9592170 42.7900 3.5 -4.90000e+01 1.990e-02 KSbCl6 / CH3CN, sat. LIT: IUPAC (2001)
Te123 26.1697420 0.8900 0.5 0.00000e+00 1.640e-04 Me2Te, neat/C6D6 LIT: IUPAC (2001)
Te125 31.5497690 7.0700 0.5 0.00000e+00 2.280e-03 Me2Te, neat/C6D6 LIT: IUPAC (2001)
I127 20.0074860 100.0000 2.5 -7.10000e+01 9.540e-02 KI / D2O, 0.01 M LIT: IUPAC (2001)
Xe129 27.8101860 26.4400 0.5 0.00000e+00 5.720e-03 XeOF4 (neat) LIT: IUPAC (2001)
Xe131 8.2439210 21.1800 1.5 -1.14000e+01 5.960e-04 XeOF4 (neat) LIT: IUPAC (2001)
Cs133 13.1161420 100.0000 3.5 -3.43000e-01 4.840e-02 CsNO3 / D2O, 0.1 M LIT: IUPAC (2001)
Ba135 9.9344570 6.5920 1.5 1.60000e+01 3.300e-04 BaCl2 / D2O, 0.5 M LIT: IUPAC (2001)
Ba137 11.1129280 11.2320 1.5 2.45000e+01 7.870e-04 BaCl2 / D2O, 0.5 M LIT: IUPAC (2001)
La138 13.1943000 0.0900 5.0 4.50000e+01 8.460e-05 LaCl3 / D2O/H2O LIT: IUPAC (2001)
La139 14.1256410 99.9100 3.5 2.00000e+01 6.050e-02 LaCl3 / D2O, 0.01 M LIT: IUPAC (2001)
Pr141 30.6200000 100.0000 2.5 -5.89000e+00 3.350e-01 (approx.) LIT: IUPAC (2001)
Nd143 5.4500000 12.2000 3.5 -6.30000e+01 4.150e-04 (approx.) LIT: IUPAC (2001)
Nd145 3.3600000 8.3000 3.5 -3.30000e+01 6.610e-05 (approx.) LIT: IUPAC (2001)
Sm147 4.1700000 14.9900 3.5 -2.59000e+01 2.280e-04 (approx.) LIT: IUPAC (2001)
Sm149 3.4400000 13.8200 3.5 7.40000e+00 1.182e-04 (approx.) LIT: IUPAC (2001)
Eu151 24.8600000 47.8100 2.5 9.03000e+01 8.570e-02 (approx.) LIT: IUPAC (2001)
Eu153 10.9800000 52.1900 2.5 2.41200e+02 8.060e-03 (approx.) LIT: IUPAC (2001)
Gd155 3.0700000 14.8000 1.5 1.27000e+02 2.140e-05 (approx.) LIT: IUPAC (2001)
Gd157 4.0300000 15.6500 1.5 1.35000e+02 5.120e-05 (approx.) LIT: IUPAC (2001)
Tb159 24.0400000 100.0000 1.5 1.43200e+02 6.950e-02 (approx.) LIT: IUPAC (2001)
Dy161 3.4400000 18.9100 2.5 2.50700e+02 8.980e-05 (approx.) LIT: IUPAC (2001)
Dy163 4.8200000 24.9000 2.5 2.64800e+02 3.250e-04 (approx.) LIT: IUPAC (2001)
Ho165 21.3400000 100.0000 3.5 3.58000e+02 2.040e-01 (approx.) LIT: IUPAC (2001)
Er167 2.8800000 22.9300 3.5 3.56500e+02 1.150e-04 (approx.) LIT: IUPAC (2001)
Tm169 8.2900000 100.0000 0.5 0.00000e+00 5.700e-04 (approx.) LIT: IUPAC (2001)
Yb171 17.4993060 14.2800 0.5 0.00000e+00 7.650e-04 Yb((eta)-C5(CH3)5)2(THF)2 0.171M in THF solution LIT: IUPAC (2001)
Yb173 4.8210000 16.1300 2.5 2.80000e+02 2.110e-04 (approx.) LIT: IUPAC (2001)
Lu175 11.4040000 97.4100 3.5 3.49000e+02 3.030e-02 (approx.) LIT: IUPAC (2001)
Lu176 8.1310000 2.5900 7.0 4.97000e+02 1.040e-03 (approx.) LIT: IUPAC (2001)
Hf177 4.0070000 18.6000 3.5 3.36500e+02 2.610e-04 (approx.) LIT: IUPAC (2001)
Hf179 2.5170000 13.6200 4.5 3.79300e+02 7.450e-05 (approx.) LIT: IUPAC (2001)
Ta181 11.9896000 99.9880 3.5 3.17000e+02 3.740e-02 KTaCl6 / CH3CN, sat. LIT: IUPAC (2001)
W183 4.1663870 14.3100 0.5 0.00000e+00 1.070e-05 Na2WO4 / D2O, 1 M LIT: IUPAC (2001)
Re185 22.5246000 37.4000 2.5 2.18000e+02 5.190e-02 KReO4 / D2O, 0.1 M LIT: IUPAC (2001)
Re187 22.7516000 62.6000 2.5 2.07000e+02 8.950e-02 KReO4 / D2O, 0.1 M LIT: IUPAC (2001)
Os187 2.2823310 1.9600 0.5 0.00000e+00 2.430e-07 OsO4 / CCl4, 0.98 M LIT: IUPAC (2001)
Os189 7.7654000 16.1500 1.5 8.56000e+01 3.950e-04 OsO4 / CCl4, 0.98 M LIT: IUPAC (2001)
Ir191 1.7180000 37.3000 1.5 8.16000e+01 1.090e-05 (approx.) LIT: IUPAC (2001)
Ir193 1.8710000 62.7000 1.5 7.51000e+01 2.340e-05 (approx.) LIT: IUPAC (2001)
Pt195 21.4967840 33.8320 0.5 0.00000e+00 3.510e-03 Na2PtCl6 / D2O, 1.2 M LIT: IUPAC (2001)
Au197 1.7290000 100.0000 1.5 5.47000e+01 2.770e-05 (approx.) LIT: IUPAC (2001)
Hg199 17.9108220 16.8700 0.5 0.00000e+00 1.000e-03 Me2Hg (neat) LIT: IUPAC (2001)
Hg201 6.6115830 13.1800 1.5 3.86000e+01 1.970e-04 (CH3)2Hg (neat) LIT: IUPAC (2001)
Tl203 57.1232000 29.5240 0.5 0.00000e+00 5.790e-02 Tl(NO3)3 LIT: IUPAC (2001)
Tl205 57.6838380 70.4760 0.5 0.00000e+00 1.420e-01 Tl(NO3)3 LIT: IUPAC (2001)
Pb207 20.9205990 22.1000 0.5 0.00000e+00 2.010e-03 Me4Pb, neat/C6D6 LIT: IUPAC (2001)
Bi209 16.0692880 100.0000 4.5 -5.16000e+01 1.440e-01 Bi(NO3)2 / HNO3/D2O/H2O LIT: IUPAC (2001)
U235 1.8414000 0.7200 3.5 4.93600e+02 9.440e-07 UF6 neat (+ 10% C6D6) LIT: IUPAC (2001)